Skip to content

    FREE Shipping on orders of $150 or more. Shop

    What does an HPLC purity percentage mean on a peptide COA?

    An HPLC purity percentage is the main peak's share of the total peak area in a chromatogram. It describes how much of the detected signal comes from the target compound. It does not give identity or the amount in the vial.

    What is HPLC purity?

    HPLC stands for high-performance liquid chromatography. A liquid carries the sample through a column, and the components of the sample leave the column at different times. A detector records each one as a peak. The purity figure on a certificate comes from comparing those peaks. Bachem, a peptide manufacturer, puts it this way: the area of the main peak in relation to the total area of all peaks reflects the peptide purity.

    So purity here is a ratio of signals. It is not a weighed amount. A report that says "purity by HPLC" is telling you which method produced the number and what the number compares.

    How is percent peak area calculated?

    The software integrates each peak, which means it measures the area between the peak and the baseline. It then divides the main peak's area by the sum of all the peak areas and multiplies by 100.

    The worked example below uses made-up round numbers to show the arithmetic. They are not taken from any Excalibur Peptides report.

    PeakArea (arbitrary units)Share of total area
    Main peak (example)95095 %
    Other peak 1 (example)303 %
    Other peak 2 (example)202 %
    Total (example)1000100 %

    The same arithmetic is why peak area is used and not peak height. A column maker's guide states that peak area is generally more reliable than peak height for quantitative analysis. If a report lists the individual peak areas, you can repeat the division yourself and compare the result with the stated purity.

    What does an HPLC chromatogram show?

    A chromatogram is the trace the purity figure comes from. The same column maker describes it as a plot of detector signal versus time. Time runs along the horizontal axis and the detector signal along the vertical axis. Each peak is one component leaving the column.

    Part of the traceWhat it isWhat to look for
    BaselineThe detector signal when no component is leaving the column.A flat, steady line between peaks.
    Main peakThe largest peak, assigned to the target compound.Where it sits in time and how much of the trace it fills.
    Other peaksOther components the detector recorded.How many there are and how large they are next to the main peak.
    Retention timeThe time from the start of the run to the top of a peak.The time printed for the main peak.
    Time axisThe horizontal axis, in minutes.That the run is long enough to show late peaks.

    Peptide purity is usually read with a UV detector, which measures how much ultraviolet light the components absorb as they pass. The detector sees only what absorbs at its setting. That matters in the next section.

    What does an HPLC purity figure not tell you?

    A purity percentage answers one narrow question. It leaves out three things a buyer often assumes it covers.

    QuestionDoes HPLC purity answer it?Where the answer comes from
    Is the main peak the intended compound?No. A peak has a retention time, not a name.The identity result, by mass spectrometry. See LC-MS identity.
    How much compound is in the vial?No. The figure is a ratio of signals, not a mass.A content result in mg. See purity and net peptide content.
    How much salt and water is in the powder?No. The detector does not see most of it.A water measurement and a net content result.

    Bachem notes that most peptides also contain trifluoroacetic acid or acetic acid as counter-ions, and that lyophilized products contain trace water. These are part of the powder. They are not part of the peptide peak.

    Two different compounds can also leave the column at nearly the same time and show as one peak. A single run does not rule that out. This is one reason a certificate pairs the purity result with an identity result.

    Where does HPLC purity appear on a certificate?

    On the certificates Freedom Diagnostics Testing issues for Excalibur Peptides, the methods are stated as "Purity by HPLC; identity by LC-MS (Freedom Diagnostics Testing)." The purity field holds the HPLC percentage, and the report includes the HPLC chromatogram, the trace the percentage comes from. The current reports show the chromatogram as a labelled image and do not list a peak-area table, so the division in the worked example cannot be repeated from those reports. It applies to reports that do list the areas.

    The purity field sits beside the identity result and the net content field. Read them as three separate results. How to read a peptide COA goes through the whole report in order, and how to verify a peptide COA explains how to confirm a report with the laboratory. The COA page describes what each field shows, and the glossary defines the terms used here.

    What should you check when you see a purity figure?

    1. Find the method named next to the figure. It should say HPLC.
    2. Open the chromatogram and find the main peak.
    3. Look at the other peaks and compare their size with the main peak.
    4. Find the identity result and the method named for it.
    5. Find the net content field and read it as a separate result.
    6. Copy the search code so the report can be confirmed with the laboratory.

    Cite this page

    Excalibur Peptides. "What does an HPLC purity percentage mean on a peptide COA?." Last updated . https://excaliburpeptides.com/guides/hplc-purity