- Accession number
The testing laboratory's own number for a sample it receives. It is printed on the certificate and identifies that sample in the laboratory's records. On the lab's reports it forms part of the search code.
See also: Search code, Certificate of analysis (COA).
- Appearance
The laboratory's written note on how the sample looks, such as its colour and form. It is an observation by eye. It is not a measurement of purity, identity or amount.
See also: Certificate of analysis (COA), Lyophilization.
- Baseline
The detector signal on a chromatogram when no component is leaving the column. A flat, steady baseline between peaks makes the peaks easier to measure. Peak areas are measured between each peak and the baseline.
See also: Chromatogram, Peak area.
- CAS number
A numerical identifier assigned by the Chemical Abstracts Service to a chemical substance. It gives one unambiguous reference for a compound whose names vary. A salt form or a mixture can carry a different number from the free form.
See also: Molecular formula, Salt form.
- Certificate of analysis (COA)
A laboratory report that gives the results of the tests run on a sample. It names the laboratory, the client, the sample, the lot and the dates, and it gives results such as purity and identity. It describes the sample tested.
See also: Lot number, Search code, Third-party testing.
- Chromatogram
The trace an HPLC run produces: detector signal plotted against time. Each peak is one component leaving the column. The purity percentage on a certificate is worked out from the areas of the peaks in this trace.
See also: HPLC, Peak area, Retention time.
- Column
The tube packed with fine particles through which a liquid carries the sample during HPLC. Components of the sample move through at different speeds and leave at different times, which is what separates them into peaks.
See also: HPLC, Retention time.
- Counter-ion
An ion of opposite charge that pairs with a charged group on the peptide to form a salt. Common examples are trifluoroacetate and acetate. Counter-ions add to the powder's mass, so they lower net peptide content.
See also: Salt form, Net content.
- Deletion sequence
A peptide impurity that lacks one or more amino acids of the intended sequence. It can form during synthesis. It usually shows as a separate, smaller peak next to the main peak on an HPLC chromatogram.
See also: Purity, Chromatogram.
- HPLC
High-performance liquid chromatography. A liquid carries a sample through a column, the components separate, and a detector records them as peaks. On a peptide certificate it is the method that gives the purity figure.
See also: Chromatogram, Purity, UV detection.
- Hygroscopic
Tending to take up moisture from the air. Many dry peptide powders are hygroscopic, which is why they are supplied in sealed vials and kept sealed in storage. Moisture uptake adds mass that is not peptide.
See also: Lyophilization, Residual water, Sealed vial.
- Identity
The result that says whether the sample is the intended compound. For a peptide it is usually shown by mass spectrometry, which compares the measured mass with the calculated mass. It is separate from the purity result.
See also: LC-MS, Mass spectrometry, Purity.
- In vitro
Latin for "in glass". It describes work done in a laboratory vessel, outside a living organism, such as work with isolated materials in a dish or tube. Research-use products are sold for this kind of laboratory work only.
See also: Research use only.
- LC-MS
Liquid chromatography coupled to mass spectrometry. The liquid chromatograph separates the components of a sample and the mass spectrometer measures the mass of each. It is the identity method on the certificates described here.
See also: Mass spectrometry, Identity, HPLC.
- Lot number
The identifier of one production lot. A certificate has a lot field for the sample it describes. The certificate describes that sample and no other.
See also: Certificate of analysis (COA), Sealed vial.
- Lyophilization
Freeze-drying. The material is frozen and then placed under vacuum so the frozen water leaves as vapor. The result is a dry powder or cake with low water content, which is why peptides are supplied this way.
See also: Residual water, Sealed vial, Hygroscopic.
- Mass spectrometry
A technique that measures the mass-to-charge ratio of ions. A mass spectrum plots the relative abundance of ion signals against m/z. It is used to find the molecular mass of a compound and so to confirm its identity.
See also: LC-MS, m/z, Molecular weight.
- Molecular formula
The count of each kind of atom in one molecule of a compound, written as symbols and numbers. The calculated mass of a compound comes from its molecular formula, so it is the starting point for an identity check.
See also: Molecular weight, Mass spectrometry.
- Molecular weight
The mass of one molecule of a compound, found by adding the atomic masses in its molecular formula. It is usually given in daltons or g/mol. The salt form changes it, so check which form a figure refers to.
See also: Molecular formula, Salt form, Mass spectrometry.
- m/z
The mass-to-charge ratio, the quantity a mass spectrometer measures. A molecule carrying several charges appears at a lower m/z than its mass. The same compound can therefore show a series of peaks at different charge states.
See also: Mass spectrometry, LC-MS.
- Net content
On the certificates described here, the amount of compound the laboratory measured in the tested sample, in mg. It is separate from purity. Counter-ions and residual water are part of the powder but not of the compound.
See also: Purity, Counter-ion, Residual water.
- Net peptide content
The share of a powder's mass that is peptide, after counter-ions, residual water and other non-peptide material. It is a different figure from purity, which compares peaks. The two are not equivalent.
See also: Purity, Net content, Counter-ion.
- Peak area
The area under one peak on a chromatogram, measured down to the baseline. Percent peak area is the main peak's area divided by the total of all peak areas, multiplied by 100. It gives the purity figure.
See also: Purity, Chromatogram, Baseline.
- Purity
On a peptide certificate, the share of the detected peptide signal that comes from the target compound, worked out from HPLC peak areas. It does not show identity, the amount in the vial, or the salt and water in the powder.
See also: HPLC, Peak area, Net peptide content.
- Reference standard
A well-characterised material used as a point of comparison in an analysis. A laboratory may compare a sample's retention time or mass with the reference. The certificate says what, if anything, was used as a reference.
See also: Retention time, Identity.
- Research use only
A label meaning the product is sold for laboratory research and for no other use. It states the permitted purpose of the product. It is not a quality grade and not a statement about the contents.
See also: In vitro, Safety data sheet (SDS).
- Residual water
The small amount of moisture that remains in a freeze-dried powder. It is part of the powder's mass but not of the peptide. Water content is commonly measured by the Karl Fischer method and lowers net peptide content.
See also: Lyophilization, Net peptide content, Hygroscopic.
- Retention time
The time from the start of an HPLC run to the top of a peak. A given compound leaves the column at a characteristic time under fixed conditions. A retention time alone does not name the compound.
See also: Chromatogram, Column, Reference standard.
- Safety data sheet (SDS)
A standard document that gives hazard, handling and storage information for a chemical product.
See also: Sealed vial, Research use only.
- Salt form
The form in which a peptide is supplied together with its counter-ion, for example as an acetate or trifluoroacetate salt. The salt form changes the molecular weight and the net peptide content of the powder.
See also: Counter-ion, Molecular weight, Net peptide content.
- Search code
The reference printed on a certificate for finding it on Freedom Diagnostics Testing's lookup page. The lab builds it from the first four characters of the client name followed by the accession number.
See also: Accession number, Certificate of analysis (COA).
- Sealed vial
A glass vial closed with a stopper and cap so the dry contents are kept from room air. An intact seal is part of what keeps a freeze-dried powder dry in storage. Storage guidance applies to the vial with its seal unbroken.
See also: Lyophilization, Hygroscopic, Lot number.
- Sequence
The order of amino acids in a peptide, written as a string of letters or three-letter codes. Two peptides with the same amino acids in a different order have the same mass, so a mass alone does not confirm sequence.
See also: Molecular formula, Mass spectrometry.
- Third-party testing
Testing done by a laboratory that is separate from the company selling the product. The laboratory issues the report under its own name, so the report can be confirmed with the laboratory directly.
See also: Certificate of analysis (COA), Search code.
- UV detection
A way of detecting components in HPLC by measuring how much ultraviolet light they absorb as they leave the column. It sees only what absorbs light at its setting, so it does not register most salts or water.
See also: HPLC, Purity, Chromatogram.